Effects of cyclic pulsed operation on the coil performance in the Nb[sub 3]Sn Demo Poloidal Coil (DPC-EX)

Conference · · IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers); (United States)
OSTI ID:6399849
; ;  [1]
  1. Japan Atomic Energy Research Inst., Ibaraki (Japan). Naka Fusion Research Establishment; and others
The effect of cyclic pulsed operation on the coil performance was studied form the electrical and mechanical points of view in the second experiment of the Nb[sub 3]Sn Demo Poloidal Coil (DPC-EX). Current sharing temperatures, ac losses, displacements, and strains were measured before and after cyclic pulsed operation, which consisted of about 350 cycles. No degradation of the electrical and mechanical performance of the DPC-EX was observed in the range of these cycles.