Title: The effects of water quality on pile operation

Technical Report ·
DOI:https://doi.org/10.2172/6397260· OSTI ID:6397260

Tests have been made to study the effects of lowering process water pH from pH 7.7 to the range pH 6.2--7.3; of reducing the amount of sodium dichromate inhibitor added to the water; and of eliminating the filtration step in the water treatment process. The results on the pH testing showed that reducing the pH of the cooling water would reduce aluminum corrosion rates. The plant specification has been changed to lower process water pH from 7.7 to 7.3 and plant scale testing of pH 7.0 water is in progress. Reducing the dichromate concentration in the water from 2 to 0.2 ppm had no deleterious effects on the aluminium pile components but might cause pitting of the carbon steel pile effluent lines. The use of unfiltered water is technically feasible from the stand-points of corrosion and film formation but probably would cause a sizable increase in the radioactivity of the pile effluent water. 6 figs., 5 tabs.

Research Organization:
General Electric Co., Richland, WA (United States). Hanford Atomic Products Operation
Sponsoring Organization:
DOE/DP
DOE Contract Number:
AC06-76RL01830
OSTI ID:
6397260
Report Number(s):
HW-34544; ON: DE91002681
Resource Relation:
Other Information: Declassified 1 Nov 1990
Country of Publication:
United States
Language:
English