TRU (transuranic) waste certification compliance requirements for acceptance of contact-handled wastes retrieved from storage to be shipped to the Waste Isolation Pilot Plant: Revision 2

Technical Report ·
OSTI ID:6377984

Compliance requirements are presented for certifying that unclassified, contact-handled (CH) transuranic (TRU) solid defense wastes retrieved from storage at DOE sites meet the Waste Isolation Pilot Plant (WIPP) Waste Acceptance Criteria (WAC). All applicable Department of Energy (DOE) orders must continue to be met. The compliance requirements for acceptance of newly generated CH waste to be shipped to the WIPP are addressed in another document. The compliance requirements are divided into four sections, primarily determined by the general feature that the requirements address. These sections are General Requirements, Waste Container Requirements, Waste Form Requirements, and Waste Package Requirements. The waste package is the combination of waste container and waste. 10 refs., 1 fig.

Research Organization:
Westinghouse Electric Corp., Carlsbad, NM (USA). Waste Isolation Div.
DOE Contract Number:
AC04-86AL31950
OSTI ID:
6377984
Report Number(s):
WIPP-DOE-137-Rev.2; ON: DE89007445
Country of Publication:
United States
Language:
English