Regulation of the flow rate of liquid-metal coolants on experimental stands
Systems for automatic regulation of the flow rate of alkali metals, based on the series ENIV, VIN, and TsLIN three-phase electromagnetic pumps with a pumping rate of 0.5-200 m/sup 3/ per hour, were evaluated. The stability of each system was investigated by the method of undamped oscillations. The possibility of employing the analog temperature regulators VRT-2, RPA-T, and R113 was assessed. The functions performed by the most suitable automatic regulation unit, the RPA-T, were described. The limiting period of flow rate oscillations with a maximum gain of the RPA-T in alkali metal regulation systems equaled about 0.5 sec and the minimum integration time of the RPA-T was an order of magnitude longer than the optimal interval. Use of the systems on experimental stands enabled raising the quality of the studies and expanding the zone of servicing of the facilities by the same personnel.
- OSTI ID:
- 6376710
- Journal Information:
- Sov. At. Energy (Engl. Transl.); (United States), Vol. 63:5; Other Information: Translated from Sov. At. Energy; 63: No. 5, 354-356(Nov 1987)
- Country of Publication:
- United States
- Language:
- English
Similar Records
Low Cost (CAPEX and variable): Tool design for cell and module fabrication with thin, free-standing silicon wafers
Cation promotion effects in zeolite-supported F-T catalysts. Seventh quarterly report, March 1985-May 1985
Related Subjects
FLOW REGULATORS
PERFORMANCE TESTING
LIQUID METAL COOLED REACTORS
REACTOR COOLING SYSTEMS
LIQUID METALS
FLOW RATE
AUTOMATION
ELECTROMAGNETIC PUMPS
HEAT TRANSFER
HYDRAULICS
POTASSIUM
POTASSIUM COOLED REACTORS
SODIUM
SODIUM COOLED REACTORS
TEMPERATURE CONTROL
TEST FACILITIES
ALKALI METALS
CONTROL
CONTROL EQUIPMENT
COOLING SYSTEMS
ELEMENTS
ENERGY SYSTEMS
ENERGY TRANSFER
EQUIPMENT
FLUID MECHANICS
FLUIDS
LIQUIDS
MECHANICS
METALS
PUMPS
REACTOR COMPONENTS
REACTORS
TESTING
220200* - Nuclear Reactor Technology- Components & Accessories