Estimating performance/costs of retrofitting control technologies at 12 coal-fired power plants. Report for November 1985-February 1987
Technical Report
·
OSTI ID:6373883
The paper gives results of estimating performance/costs of retrofitting pollution control technologies at 12 coal-fired power plants. In cooperation with the states of Ohio and Kentucky (in conjunction with EPA's state acid-rain program), efforts were undertaken to visit and conduct detailed evaluations of 12 coal-fired plants--5 in Ohio and 7 in Kentucky and the Tennessee Valley Authority system. A variety of commercial and advanced SO/sub 2/ and NOx control technologies--including precombustion, combustion (in-furnace), and post-combustion (flue-gas cleanup) technologies--were applied to each plant through conceptual designs. Retrofit factors (applied to the capital cost of a new pollution-control system), cost adders (e.g., movement of existing equipment), and costs were developed for applying the control technologies to the boilers of each plant. Results of these and subsequent efforts will be valuable in evaluations of acid-deposition control strategies by federal and state agencies and by electric utilities.
- Research Organization:
- Radian Corp., Research Triangle Park, NC (USA)
- OSTI ID:
- 6373883
- Report Number(s):
- PB-87-175832/XAB
- Country of Publication:
- United States
- Language:
- English
Similar Records
Performance/cost estimates for retrofitting control technologies at 12 coal-fired power plants
Ohio/Kentucky/TVA (Tennessee Valley Authority) coal-fired utility SO/sub 2/ and NOx control retrofit study. Final report, October 1985-September 1987
Estimating performance and costs of retrofit SO/sub 2/ and NOx controls for acid-rain abatement. Report for November 1985-January 1988
Technical Report
·
Thu Dec 31 23:00:00 EST 1987
·
OSTI ID:6679642
Ohio/Kentucky/TVA (Tennessee Valley Authority) coal-fired utility SO/sub 2/ and NOx control retrofit study. Final report, October 1985-September 1987
Technical Report
·
Mon Aug 01 00:00:00 EDT 1988
·
OSTI ID:7065721
Estimating performance and costs of retrofit SO/sub 2/ and NOx controls for acid-rain abatement. Report for November 1985-January 1988
Technical Report
·
Mon Aug 01 00:00:00 EDT 1988
·
OSTI ID:6741567
Related Subjects
20 FOSSIL-FUELED POWER PLANTS
200202* -- Fossil-Fueled Power Plants-- Waste Management-- Noxious Gas & Particulate Emissions
ACID RAIN
AIR POLLUTION ABATEMENT
ATMOSPHERIC PRECIPITATIONS
BOILERS
CHALCOGENIDES
EQUIPMENT
FOSSIL-FUEL POWER PLANTS
NAPAP
OXIDES
OXYGEN COMPOUNDS
PERFORMANCE
POLLUTION ABATEMENT
POLLUTION CONTROL EQUIPMENT
POWER PLANTS
RAIN
RETROFITTING
SULFUR COMPOUNDS
SULFUR DIOXIDE
SULFUR OXIDES
THERMAL POWER PLANTS
200202* -- Fossil-Fueled Power Plants-- Waste Management-- Noxious Gas & Particulate Emissions
ACID RAIN
AIR POLLUTION ABATEMENT
ATMOSPHERIC PRECIPITATIONS
BOILERS
CHALCOGENIDES
EQUIPMENT
FOSSIL-FUEL POWER PLANTS
NAPAP
OXIDES
OXYGEN COMPOUNDS
PERFORMANCE
POLLUTION ABATEMENT
POLLUTION CONTROL EQUIPMENT
POWER PLANTS
RAIN
RETROFITTING
SULFUR COMPOUNDS
SULFUR DIOXIDE
SULFUR OXIDES
THERMAL POWER PLANTS