The Westinghouse Hanford Company is installing a remotely operated Contaminated Sodium Recovery System (CSRS) at the Fast Flux Test Facility (FFTF) located in Richland, Washington. The CSRS will recover activated sodium that accumulates in fuel transfer machines during core component transfer operations. Drip pots from the FFTF fuel handling machines will be delivered to the shielded, argon-inerted Interim Examination and Maintenance (IEM) Cell, a hot cell located in the FFTF containment structure. Installation of the CSRS replaces a previously manual operation that required disposal of radioactive sodium with a completely remote operation that will return sodium to service in the plant. The CSRS will minimize the accumulation of hazardous waste and reduce personnel exposure to radioactive materials. Equipment for the CSRS is currently being fabricated and tested before installation in the IEM Cell. 6 figs.