Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Arapahoe low-sulfur-coal Fabric Filter Pilot Plant: Volume 4, Shake-deflate cleaning tests, May 1984--July 1986: Final report

Technical Report ·
OSTI ID:6362957
This report describes operations at EPRI's low-sulfur coal Fabric Filter Pilot Plant during a twenty-seven month evaluation of shake-deflate cleaning. The primary objective was to collect sufficient data to optimize shake-deflate parameters and to allow prediction of baghouses operation with this cleaning method at utility power plants burning low-sulfur coal. The tests evaluated baghouse performance (pressure drop at various filtering air-to-cloth ratios, dustcake weight, and emissions) as a function of bag-cap acceleration, shake frequency, shake duration, and deflation volume. The findings indicate that shake-deflate cleaning can reduce cake weight and tube-sheet pressure drops by greater than 50% over conventional reverse-gas cleaned units. No bag life problems were observed over 11,000 h of testing, and emissions were very low (0.006 lb/10/sup 6/ Btu). Minimum filter pressure drop was attained at a bag-cap acceleration of 1.4 g (amplitude 2 in. and frequency 3 Hz). Low frequency high-amplitude shaking was more effective than high-frequency low-amplitude shaking. Shake durations around 20 s (at 3 Hz) preceded by deflation flows equivalent to about one-sixth total bag volume (1 ft/min deflation flow for 3 s) gave optimal performance. 9 refs., 12 figs., 5 tabs.
Research Organization:
Electric Power Research Inst., Palo Alto, CA (USA); Southern Research Inst., Birmingham, AL (USA)
OSTI ID:
6362957
Report Number(s):
EPRI-CS-3862-Vol.4
Country of Publication:
United States
Language:
English