Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

A high performance anticoincidence rejection system for balloon borne MWPC

Conference · · IEEE Trans. Nucl. Sci.; (United States)
OSTI ID:6359273
The supernova SN1987A have been observed in the range of hard X-rays (15 / 180 KeV) and high energy ..gamma..-rays (50 / 500 MeV) with a payload launched from the balloon facility of Alice Springs (Australia) during April 1987 and 1988. The low energy detector based on a MWPC had a sensitive area of 500 cm/sup 2/. In the second flight a complete plastic shield was added for the first time to the Multiwire Proportional Counter (MWPC). In this way, switching on the active shield, the background counting rate dropped from 4.2 to 2.8 x 10/sup -4/ ct/cm/sup 2/ s keV with no change in the dead time of the counter. This clearly demonstrates the advantage of the use of a multitechnique rejection system for this kind of gaseous detectors.
Research Organization:
Istituto di Astrofisica Spaziale, Frascati (IT); Institute of High Energy Physics, Academia Sinica, PRC
OSTI ID:
6359273
Report Number(s):
CONF-881103-
Conference Information:
Journal Name: IEEE Trans. Nucl. Sci.; (United States) Journal Volume: 36:1
Country of Publication:
United States
Language:
English