Initial characterization of a position-sensitive photodiode/BGO detector for PET (positron emission tomography)
Conference
·
OSTI ID:6353824
We present initial results of a position-sensitive photodiode/BGO detector for high resolution, multi-layer positron emission tomography (PET). Position sensitivity is achieved by dividing the 3 mm /times/ 20 mm rectangular photosensitive area along the diagonal to form two triangular segments. Each segment was individually connected to a low-noise amplifier. The photodiodes and crystals were cooled to /minus/100/degree/C to reduce dark current and increase the BGO signal. With an amplifier peaking time of 17 ..mu..sec, the sum of the signals (511 keV photopeak) was 3200 electrons with a full width at half maximum (fwhm) of 750 electrons. The ratio of one signal to the sum determined the depth of interaction with a resolution of 11 mm fwhm. 27 refs., 7 figs.
- Research Organization:
- Lawrence Berkeley Lab., CA (USA)
- DOE Contract Number:
- AC03-76SF00098
- OSTI ID:
- 6353824
- Report Number(s):
- LBL-26529; CONF-881103-54; ON: DE89007660
- Country of Publication:
- United States
- Language:
- English
Similar Records
Initial characterization of a position-sensitive photodiode/BGO detector for PET
Initial characterization of a bgo-Photodiode detector for high resolution positron emission tomography
Initial characterization of a BGO-photodiode detector for high resolution positron emission tomography
Conference
·
Tue Jan 31 23:00:00 EST 1989
· IEEE Trans. Nucl. Sci.; (United States)
·
OSTI ID:6359542
Initial characterization of a bgo-Photodiode detector for high resolution positron emission tomography
Conference
·
Tue Jan 31 23:00:00 EST 1984
· IEEE Trans. Nucl. Sci.; (United States)
·
OSTI ID:6850524
Initial characterization of a BGO-photodiode detector for high resolution positron emission tomography
Conference
·
Mon Oct 31 23:00:00 EST 1983
·
OSTI ID:5273042
Related Subjects
07 ISOTOPE AND RADIATION SOURCES
440103* -- Radiation Instrumentation-- Nuclear Spectroscopic Instrumentation
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
61 RADIATION PROTECTION AND DOSIMETRY
655002 -- Medical Physics-- Radiation Source Calibration & Standardization
655003 -- Medical Physics-- Dosimetry
BGO DETECTORS
CHARGED PARTICLE DETECTION
COMPUTERIZED TOMOGRAPHY
DETECTION
DIAGNOSTIC TECHNIQUES
EFFICIENCY
EMISSION COMPUTED TOMOGRAPHY
GAMMA DETECTION
IMAGE INTENSIFIERS
IMAGE SCANNERS
MEASURING INSTRUMENTS
OPTIMIZATION
POSITRON COMPUTED TOMOGRAPHY
POSITRON DETECTION
RADIATION DETECTION
RADIATION DETECTORS
RESOLUTION
SCINTILLATION COUNTERS
SCINTILLATOR-PHOTODIODE DETECTORS
SOLID SCINTILLATION DETECTORS
SPATIAL RESOLUTION
TOMOGRAPHY
440103* -- Radiation Instrumentation-- Nuclear Spectroscopic Instrumentation
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
61 RADIATION PROTECTION AND DOSIMETRY
655002 -- Medical Physics-- Radiation Source Calibration & Standardization
655003 -- Medical Physics-- Dosimetry
BGO DETECTORS
CHARGED PARTICLE DETECTION
COMPUTERIZED TOMOGRAPHY
DETECTION
DIAGNOSTIC TECHNIQUES
EFFICIENCY
EMISSION COMPUTED TOMOGRAPHY
GAMMA DETECTION
IMAGE INTENSIFIERS
IMAGE SCANNERS
MEASURING INSTRUMENTS
OPTIMIZATION
POSITRON COMPUTED TOMOGRAPHY
POSITRON DETECTION
RADIATION DETECTION
RADIATION DETECTORS
RESOLUTION
SCINTILLATION COUNTERS
SCINTILLATOR-PHOTODIODE DETECTORS
SOLID SCINTILLATION DETECTORS
SPATIAL RESOLUTION
TOMOGRAPHY