Solar project description for John Byram, Jr. single-family residence; Shawnee Mission, Kansas

Technical Report ·
DOI:https://doi.org/10.2172/6349539· OSTI ID:6349539
The active solar heating system utilized for space heat and domestic hot water includes 312 square feet of roof-mounted flat plate air collectors and 172-cubic feet pebble bed heat storage unit. A gas-fired furnace is used for auxiliary space heating and a gas fired domestic water heater is used for hot water. A passive system consisting of an attached greenhouse and a Trombe wall is also included. The collectors, storage, energy-to-load, and auxiliary subsystems are described. Specific details of the operating modes and controls are also given.
Research Organization:
Department of Housing and Urban Development, Washington, DC (USA); Boeing Co., Seattle, WA (USA)
DOE Contract Number:
AB01-76CS31020
OSTI ID:
6349539
Report Number(s):
SOLAR/1004-81/50; ON: DE81025175
Country of Publication:
United States
Language:
English