Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Digital impedance for faradaic analysis III. copper corrosion in oxygenated 0. 1N HC1

Journal Article · · J. Electrochem. Soc.; (United States)
DOI:https://doi.org/10.1149/1.2114165· OSTI ID:6349143

Impedance measurements have been made on copper rotating disks corroding in oxygenated 0.1N HC1. A model is developed here for the first time for the faradaic impedance of a corrosion couple consisting of an anodic dissolution reaction dominated by convective diffusion and a cathodic reaction under kinetic control. The model was found to be obeyed for all values of disk rotation rate, oxygen concentration, and voltage excitation frequency. The corrosion rate was found to depend on oxygen concentration to the 2/3 power, and on rotation rate to the 1/6 power.

Research Organization:
Sandia National Laboratories, Division 1841, Albuquerque, New Mexico
OSTI ID:
6349143
Journal Information:
J. Electrochem. Soc.; (United States), Journal Name: J. Electrochem. Soc.; (United States) Vol. 132:8; ISSN JESOA
Country of Publication:
United States
Language: