Title: Self-actuated shutdown-system development: system response-analysis status

Technical Report ·
OSTI ID:6347898

This report provides a preliminary evaluation of the SASS response time requirements for the safe shutdown earthquake (SSE), the flow coastdown (FCD), and two transient overpower (TOP) events. The driving functions for the SSE are a 20 cent step reactivity insertion with a +- 60 cent oscillation super imposed for 10 seconds combined with a flow coastdown defined by F/F/sub (0)/ = 1/(1+.2788t). The driving function of the FCD is just the relative flow curve defined above for the SSE. The TOP event driving function represents a control rod runout to a total of 60 cents at ramp rates of .76 cents/s and 6.1 cents/s. 3 figures.

Research Organization:
General Electric Co., Sunnyvale, CA (USA). Advanced Reactor Systems Dept.
DOE Contract Number:
AT03-76SF71032
OSTI ID:
6347898
Report Number(s):
DOE/SF/71032-T13; ON: DE81025239; TRN: 81-012133
Country of Publication:
United States
Language:
English