Title: Adaptive optimal control of steam temperatures for thermal power plants

Journal Article · · IEEE Trans. Power Electronics; (United States)
DOI:https://doi.org/10.1109/60.23146· OSTI ID:6345354

An adaptive optimal control method using a process control computer was developed for boiler steam temperature control for thermal power plants. A process dynamics model, which describes the dynamic plant behavior, is used in the calculations for adaptive optimal control. The model employed is a multi-input and output ARMA (autoregressive moving average) with parameters identified on-line by the Kalman filter method.