Epoxy replication for Wolter x-ray microscope fabrication

Conference ·
DOI:https://doi.org/10.1063/1.33137· OSTI ID:6329644
An epoxy replica of a test piece designed to simulate a Wolter x-ray microscope geometry showed no loss of x-ray reflectivity or resolution, compared to the original. The test piece was a diamond-turned cone with 1.5/sup 0/ half angle. A flat was fly-cut on one side, then super- and conventionally polished. The replica was separated at the 1.5/sup 0/-draft angle, simulating a shallow angle Wolter microscope geometry. A test with 8.34 A x rays at 0.9/sup 0/ grazing angle showed a reflectivity of 67% for the replica flat surface, and 70% for the original. No spread of the reflected beam was observed with a 20-arc second wide test beam. This test verifies the epoxy replication technique for production of Wolter x-ray microscopes.