skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Effects of sampling parameters on principal components analysis of Raman line images

Journal Article · · Applied Spectroscopy
;  [1]
  1. Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109-1055 (United States of America)

Raman images of the distribution of materials in a sample prepared from 10 um diameter polystyrene spheres embedded in epoxy were reconstructed from sets of line-scanned images, with the use of univariate and multivariate processing of the spectral data. Multiple sets of microscopic Raman spectral line images were acquired by using line-focused illumination with a cylindrical lens, a motorized translation stage to move the sample perpendicular to the illumination line, and a holographic imaging spectrograph equipped with a 2D charge-coupled device detector. Repeat sets of data were obtained at different spectrometer slit width settings and different magnification. The raw spectral data was processed by using both a simple univariate method (single-band integration) and a more sophisticated multivariate method (principal components analysis with eigenvector rotation) to generate 2D Raman images representing spatial distribution of the individual polymeric constituents. The repeat data sets were compared to ascertain the effects of the sampling parameters on the principal components analysis (PCA) method. The results indicated that spectrometer slit width and magnification affect the sampling depth and spatial resolution, but have little effect on the PCA. Moreover, digital sampling (i.e., number of PCA wavelength variables) could be significantly reduced with little or no degradation of the PCA-generated images, particularly if key bands were represented. {copyright} {ital 1996} {ital Society for Applied Spectroscopy}

Sponsoring Organization:
USDOE
DOE Contract Number:
FG02-89ER13996
OSTI ID:
632530
Journal Information:
Applied Spectroscopy, Vol. 50, Issue 6; Other Information: PBD: Jun 1996
Country of Publication:
United States
Language:
English

Similar Records

Spatially and temporally resolved crystal spectrometer for diagnosing high-temperature pinch plasmas on {ital Z}
Journal Article · Fri Jan 01 00:00:00 EST 1999 · Review of Scientific Instruments · OSTI ID:632530

Principal Component Analysis-Based Pattern Analysis of Dose-Volume Histograms and Influence on Rectal Toxicity
Journal Article · Sat Sep 01 00:00:00 EDT 2007 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:632530

Rotated principal component analysis of total column ozone obtained from TOMS for 1984-1989
Technical Report · Tue Dec 31 00:00:00 EST 1996 · OSTI ID:632530