Effects of sampling parameters on principal components analysis of Raman line images
Journal Article
·
· Applied Spectroscopy
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109-1055 (United States of America)
Raman images of the distribution of materials in a sample prepared from 10 um diameter polystyrene spheres embedded in epoxy were reconstructed from sets of line-scanned images, with the use of univariate and multivariate processing of the spectral data. Multiple sets of microscopic Raman spectral line images were acquired by using line-focused illumination with a cylindrical lens, a motorized translation stage to move the sample perpendicular to the illumination line, and a holographic imaging spectrograph equipped with a 2D charge-coupled device detector. Repeat sets of data were obtained at different spectrometer slit width settings and different magnification. The raw spectral data was processed by using both a simple univariate method (single-band integration) and a more sophisticated multivariate method (principal components analysis with eigenvector rotation) to generate 2D Raman images representing spatial distribution of the individual polymeric constituents. The repeat data sets were compared to ascertain the effects of the sampling parameters on the principal components analysis (PCA) method. The results indicated that spectrometer slit width and magnification affect the sampling depth and spatial resolution, but have little effect on the PCA. Moreover, digital sampling (i.e., number of PCA wavelength variables) could be significantly reduced with little or no degradation of the PCA-generated images, particularly if key bands were represented. {copyright} {ital 1996} {ital Society for Applied Spectroscopy}
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- FG02-89ER13996
- OSTI ID:
- 632530
- Journal Information:
- Applied Spectroscopy, Journal Name: Applied Spectroscopy Journal Issue: 6 Vol. 50; ISSN 0003-7028; ISSN APSPA4
- Country of Publication:
- United States
- Language:
- English
Similar Records
Phenomenology Studies Using a Scanning Fully Polarimetric Passive W-Band Millimeter Wave Imager
Spatially and temporally resolved crystal spectrometer for diagnosing high-temperature pinch plasmas on {ital Z}
Confocal Raman imaging of crystalline an glassy materials
Conference
·
Sun May 01 00:00:00 EDT 2011
·
OSTI ID:1015903
Spatially and temporally resolved crystal spectrometer for diagnosing high-temperature pinch plasmas on {ital Z}
Journal Article
·
Thu Dec 31 23:00:00 EST 1998
· Review of Scientific Instruments
·
OSTI ID:295612
Confocal Raman imaging of crystalline an glassy materials
Conference
·
Sat Dec 30 23:00:00 EST 1995
·
OSTI ID:466534