Posttest data analysis of FIST experimental TRAC-BD1/MOD1 power transient experiment
Conference
·
OSTI ID:6315015
The FIST power transient test 6PMC2 was analyzed to further the understanding of the FIST facility and provide an assessment of TRAC-BD1/MOD1. FIST power transient 6PMC2 investigated the thermal-hydraulic response following inadvertent closure of the main steam isolation valve and the subsequent failure of the reactor to scram. Failure of the high pressure core spray system was also assumed, resulting in only the reactor core isolation cooling flow for inventory makeup during the transient. The experiment was a sensitivity study with relatively high core power and low makeup rates. This study provides one of the first opportunities to assess TRAC-BD1/MOD1 under power transient and natural circulation conditions with data from a facility with prototypical BWR geometry. The power transient test was analyzed with emphasis on the following phenomena: (a) the system pressure response, (b) the natural circulation flows and rates, and (c) the heater rod cladding temperature response. Based on the results of this study, TRAC-BD1/MOD1 can be expected to calculate the thermal-hydraulic behavior of a BWR during a power transient.
- Research Organization:
- Idaho National Engineering Lab., Idaho Falls (USA)
- DOE Contract Number:
- AC07-76ID01570
- OSTI ID:
- 6315015
- Report Number(s):
- EGG-M-18884; CONF-8410142-46; ON: DE85003592
- Country of Publication:
- United States
- Language:
- English
Similar Records
Posttest data analysis and assessment of TRAC-BD1/MOD1 with data from a Full Integral Simulation Test (FIST) power transient experiment
Simulation of FIST tests using TRAC-BD1/MOD1
Assessment of TRAC-BD1/MOD1 using FIST data
Conference
·
Sat Dec 31 23:00:00 EST 1983
·
OSTI ID:6162646
Simulation of FIST tests using TRAC-BD1/MOD1
Conference
·
Tue Dec 31 23:00:00 EST 1985
· Trans. Am. Nucl. Soc.; (United States)
·
OSTI ID:6665096
Assessment of TRAC-BD1/MOD1 using FIST data
Conference
·
Mon Dec 31 23:00:00 EST 1984
·
OSTI ID:6206297
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
210100 -- Power Reactors
Nonbreeding
Light-Water Moderated
Boiling Water Cooled
22 GENERAL STUDIES OF NUCLEAR REACTORS
220900* -- Nuclear Reactor Technology-- Reactor Safety
ACCIDENTS
BWR TYPE REACTORS
COMPUTER CODES
REACTOR ACCIDENTS
REACTOR SAFETY EXPERIMENTS
REACTORS
SIMULATION
T CODES
TEST FACILITIES
TRANSIENT OVERPOWER ACCIDENTS
WATER COOLED REACTORS
WATER MODERATED REACTORS
210100 -- Power Reactors
Nonbreeding
Light-Water Moderated
Boiling Water Cooled
22 GENERAL STUDIES OF NUCLEAR REACTORS
220900* -- Nuclear Reactor Technology-- Reactor Safety
ACCIDENTS
BWR TYPE REACTORS
COMPUTER CODES
REACTOR ACCIDENTS
REACTOR SAFETY EXPERIMENTS
REACTORS
SIMULATION
T CODES
TEST FACILITIES
TRANSIENT OVERPOWER ACCIDENTS
WATER COOLED REACTORS