120-GeV protons from the Main Ring will be used to produce 8-GeV antiprotons. A pulsed lithium lens collects and matches the antiprotons to a beam line for injection into the Debuncher Ring. The anti p beam has a transverse emittance of 20..pi.. mm-mr and a deltap/p = +-2.0%. The beam line consists of a clean-up section with vertical emittance selection, two long dispersion free sections, a bend and a vertical injector. Antiprotons with a transverse emittance of 2..pi.. mm-mr and deltap/p = +-7.0 x 10/sup -4/ are transported in the reverse direction, bypassing the target area, and along the 120-GeV proton transport line for reverse injection in the Main Ring.