Title: TFTR horizontal high-resolution Bragg x-ray spectrometer

Technical Report ·
DOI:https://doi.org/10.2172/6296761· OSTI ID:6296761

A bent quartz crystal spectrometer of the Johann type with a spectral resolution of lambda/..delta..lambda = 10,000 to 25,000 is used on TFTR to determine central plasma parameters from the spectra of heliumlike and lithiumlike metal impurity ions (Ti, Cr, Fe, and Ni). The spectra are observed along a central radial chord and are recorded by a position sensitive multiwire proportional counter with a spatial resolution of 250. Standard delay-line time-difference readout is employed. The data are histogrammed and stored in 64k of memory providing 128 time groups of 512-channel spectra. The central ion temperature and the toroidal plasma rotation are inferred from the Doppler broadening and Doppler shift of the K lines. The central electron temperature, the distribution of ionization states, and dielectronic recombination rates are obtained from satellite-to-resonance line ratios. The performance of the spectrometer is demonstrated by measurements of the Ti XXI K radiation.

Research Organization:
Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)
DOE Contract Number:
AC02-76CH03073
OSTI ID:
6296761
Report Number(s):
PPPL-2173; ON: DE85004397
Country of Publication:
United States
Language:
English