Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Measurement of off-axis energy deposition from 100 MeV electrons traversing water and liquid nitrogen

Conference · · IEEE Trans. Nucl. Sci.; (United States)
OSTI ID:6296176
Using the Naval Postgraduate School 100 MeV linear electron accelerator, the dose delivered in water and liquid nitrogen near the axis of an electron beam was measured with calcium TLD's. The measurements presented show that calculations are able to predict dose near an electron beam. Calculations were done with CYLTRAN, a state-of-the art Monte Carlo electron/photon transport code, but as the physical basis for this and other members of the Integrated Tiger Series is the same, the use of other codes is not expected to provide significant differences. The uncertainties in the physical arrangement of dosimeters do not readily lend themselves to precision measurements, but data and calculation agree adequately over many orders of magnitude. A prescription is presented to extend results obtained in one medium (H/sub 2/O or LN/sub 2/) to another (air) where geometry considerations make experiments difficult.
Research Organization:
Naval Postgraduate School, Monterey, CA (US); Los Alamos National Lab., Los Alamos, NM (US)
OSTI ID:
6296176
Report Number(s):
CONF-880730-
Conference Information:
Journal Name: IEEE Trans. Nucl. Sci.; (United States) Journal Volume: 35:6
Country of Publication:
United States
Language:
English