Rapid and accurate diagnosis of acute cholecystitis with /sup 99m/Tc-HIDA cholescintigraphy. [HIDA = dimethyl acetanilide iminodiacetic acid]

Journal Article · · Am. J. Roentgenol.; (United States)
Technetium-99m dimethyl acetanilide iminodiacetic acid (HIDA) cholescintigraphy was performed on 90 patients with suspected acute cholecytitis. Visualization of the gallbladder established patency of the cystic duct and excluded the diagnosis of acute cholecystitis in 50 of 52 patients. Nonvisualization of the gallbladder with visualization of the common bile duct was diagnostic of acute cholecystitis in 38 patients, all subsequently proven at surgery. The observed accuracy of this procedure is 98% and specificity is 100%. The false negative rate is 5% and false positive rate is zero. Technetium-99m-HILDA has many advantages which make it the procedure of choice in evaluating a patient for suspected acute cholecystitis. It is a rapid, simple, safe examination which provides functional as well as anatomic information about the hepatobiliary system in individuals with a serum bilirubin level up to 8 mg/100 ml.
Research Organization:
Montefiore Hospital, Bronx, NY
OSTI ID:
6295736
Journal Information:
Am. J. Roentgenol.; (United States), Journal Name: Am. J. Roentgenol.; (United States) Vol. 132:4; ISSN AJROA
Country of Publication:
United States
Language:
English