Electric utility engineer`s FGD manual -- Volume 2: Major mechanical equipment; FGD proposal evaluations; Use of FGDPRISM in FGD system modification, proposal, evaluation, and design; FGD system case study. Final report

Technical Report ·
DOI:https://doi.org/10.2172/629396· OSTI ID:629396
Part 2 of this manual provides the electric utility engineer with detailed technical information on some of the major mechanical equipment used in the FGD system. The objectives of Part 2 are the following: to provide the electric utility engineer with information on equipment that may be unfamiliar to him, including ball mills, vacuum filters, and mist eliminators; and to identify the unique technique considerations imposed by an FGD system on more familiar electric utility equipment such as fans, gas dampers, piping, valves, and pumps. Part 3 provides an overview of the recommended procedures for evaluating proposals received from FGD system vendors. The objectives are to provide procedures for evaluating the technical aspects of proposals, and to provide procedures for determining the total costs of proposals considering both initial capital costs and annual operating and maintenance costs. The primary objective of Part 4 of this manual is to provide the utility engineer who has a special interest in the capabilities of FGDPRISM [Flue Gas Desulfurization PRocess Integration and Simulation Model] with more detailed discussions of its uses, requirements, and limitations. Part 5 is a case study in using this manual in the preparation of a purchase specification and in the evaluation of proposals received from vendors. The objectives are to demonstrate how the information contained in Parts 1 and 2 can be used to improve the technical content of an FGD system purchase specification; to demonstrate how the techniques presented in Part 3 can be used to evaluate proposals received in response to the purchase specification; and to illustrate how the FGDPRISM computer program can be used to establish design parameters for the specification and evaluate vendor designs.
Research Organization:
Radian International LLC, Austin, TX (United States)
Sponsoring Organization:
USDOE Assistant Secretary for Fossil Energy, Washington, DC (United States)
DOE Contract Number:
FG22-95PC94256
OSTI ID:
629396
Report Number(s):
DOE/PC/94256--99-Vol.2; ON: DE98054411
Country of Publication:
United States
Language:
English

Similar Records

The electric utility engineers` FGD manual. Introducing flue gas desulfurization concepts to the electric utility engineer
Conference · Tue Dec 30 23:00:00 EST 1997 · OSTI ID:324616

FGD damper guidelines
Technical Report · Tue Oct 31 23:00:00 EST 1989 · OSTI ID:5513785

Lime FGD Systems Data Book. Final report
Technical Report · Tue May 01 00:00:00 EDT 1979 · OSTI ID:5768109