Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Full length prototype SSC dipole test results

Conference ·
OSTI ID:6281593
Results are presented from tests of the first full length prototype SSC dipole magnet. The cryogenic behavior of the magnet during a slow cooldown to 4.5K and a slow warmup to room temperature has been measured. Magnetic field quality was measured at currents up to 2000 A. Averaged over the body field all harmonics with the exception of b/sub 2/ and b/sub 8/ are at or within the tolerances specified by the SSC Central Design Group. (The values of b/sub 2/ and b/sub 8/ result from known design and construction defects which will be be corrected in later magnets.) Using an NMR probe the average body field strength is measured to be 10.283 G/A with point to point variations on the order of one part in 1000. Data are presented on quench behavior of the magnet up to 3500 A (approximately 55% of full field) including longitudinal and transverse velocities for the first 250 msec of the quench.
Research Organization:
Fermi National Accelerator Lab., Batavia, IL (USA); Brookhaven National Lab., Upton, NY (USA); Lawrence Berkeley Lab., CA (USA)
DOE Contract Number:
AC02-76CH03000
OSTI ID:
6281593
Report Number(s):
FNAL-TM-1450; CONF-870983-1; ON: DE87010299
Country of Publication:
United States
Language:
English