CEA variable-throat venturi scrubber evaluation. Final report, May 1977--December 1977. [CEA = Combustion Equipment Associates]
Technical Report
·
OSTI ID:6278845
The report gives detailed results of fractional and overall mass efficiency tests of a Combustion Equipment Associates(CEA) variable-throat venturi scrubber. The tests were performed on a full-scale scrubber used for controlling particles and SO/sub x/ emissions from a pulverized-coal-fired utility boiler. Total flue gas particulate mass concentrations were determined at the scrubber inlet and outlet by conventional techniques. Inlet and outlet particulate concentrations as functions of size were determined on a mass basis using cascade impactors for sizes from about 0.3 to 5 ..mu.., and on a number basis for sizes smaller than about 1 micrometer using optical and electrical mobility techniques. The report describes the scrubber, measurement methods, inlet and outlet size distribution data, and fractional efficiencies.
- Research Organization:
- Southern Research Inst., Birmingham, AL (USA)
- OSTI ID:
- 6278845
- Report Number(s):
- PB-285723
- Country of Publication:
- United States
- Language:
- English
Similar Records
Evaluations of novel particulate control devices. Final report June 1974--January 1978
Apitron electrostatically augmented fabric filter evaluation. Final report, November 1977-October 1978
Measurement of sulfate aerosols from western low-rank-coal-fired boilers with FGD: results of tests at clay Boswell Unit 4
Technical Report
·
Thu Jun 01 00:00:00 EDT 1978
·
OSTI ID:6437004
Apitron electrostatically augmented fabric filter evaluation. Final report, November 1977-October 1978
Technical Report
·
Wed Jan 31 23:00:00 EST 1979
·
OSTI ID:5674870
Measurement of sulfate aerosols from western low-rank-coal-fired boilers with FGD: results of tests at clay Boswell Unit 4
Technical Report
·
Wed May 06 00:00:00 EDT 1981
·
OSTI ID:6515010
Related Subjects
20 FOSSIL-FUELED POWER PLANTS
200202* -- Fossil-Fueled Power Plants-- Waste Management-- Noxious Gas & Particulate Emissions
AIR POLLUTION CONTROL
CARBONACEOUS MATERIALS
COAL
ENERGY SOURCES
EQUIPMENT
FLUE GAS
FOSSIL FUELS
FOSSIL-FUEL POWER PLANTS
FUELS
GASEOUS WASTES
PERFORMANCE TESTING
POLLUTION CONTROL
POLLUTION CONTROL EQUIPMENT
POWER PLANTS
SCRUBBERS
SCRUBBING
TESTING
THERMAL POWER PLANTS
WASTES
200202* -- Fossil-Fueled Power Plants-- Waste Management-- Noxious Gas & Particulate Emissions
AIR POLLUTION CONTROL
CARBONACEOUS MATERIALS
COAL
ENERGY SOURCES
EQUIPMENT
FLUE GAS
FOSSIL FUELS
FOSSIL-FUEL POWER PLANTS
FUELS
GASEOUS WASTES
PERFORMANCE TESTING
POLLUTION CONTROL
POLLUTION CONTROL EQUIPMENT
POWER PLANTS
SCRUBBERS
SCRUBBING
TESTING
THERMAL POWER PLANTS
WASTES