Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Heat transfer in an air thermosyphon permafrost protection device

Journal Article · · J. Energy Resour. Technol.; (United States)
DOI:https://doi.org/10.1115/1.3230404· OSTI ID:6274745
Velocity and temperature profiles were measured in a prototype air thermosyphon permafrost protection device. This device, known as the air convection pile, consists of an 18-in. (0.46-m) outer tube containing a shorter concentric 10-in. (0.25-m) tube extending from 10 to 60 ft (3 to 18 m) into the permafrost. Measurements showed a low frequency oscillating flow in both the annulus and inner tube. Heat removal rates compared favorable with an analytical model and previous experimental results, but the annulus velocity profiles were significantly different, possibly due to the oscillation in the flow.
Research Organization:
Mechanical and Aerospace Engineering Dept., The Univ. of Tennessee, Knoxville, TN 37916
OSTI ID:
6274745
Journal Information:
J. Energy Resour. Technol.; (United States), Journal Name: J. Energy Resour. Technol.; (United States) Vol. 104:3; ISSN JERTD
Country of Publication:
United States
Language:
English