Temperature control of a continuous, push type, five zone, slab reheating furnace, for minimum fuel usage
Thesis/Dissertation
·
OSTI ID:6272092
The problem under investigation is the temperature control of a continuous, push type, slab reheat furnace for minimum fuel consumption. An existing computer simulation of the reheat furnace was tested and enhanced for the purpose of developing an on-line temperature control scheme. The results obtained include: an on-line temperature control scheme using off-line model generated data; the development of a set of off-line algorithms for determining the maximum furnace push rate; the minimum fuel usage at steady state for a specified existing average slab temperature profile; and the fuel flow distributions and push rate adjustments required during transition from one operating level to another, while maintaining existing average slab temperatures within a specified tolerance band. Two different average slab thicknesses and four different push rates were considered in this study. The furnace used in this study is located at Bethlehem Steel Corporations' Burns Harbor, Indiana, Works, 80 inch Hot Strip Mill. The geometrical and process similarity of each zone (i.e., preheat zone top, preheat zone bottom, heat zone top, etc.) allowed a simpilifcation of the model involved by considering one zone as representative of all the other zones. The model used was verified by showing that the simulation results exhibited similar responses as the real furnace to equivalent upsets with similar magnitude results and similar time responses. No absolute validation versus plant operating data was possible.
- OSTI ID:
- 6272092
- Country of Publication:
- United States
- Language:
- English
Similar Records
Temperature control of a continuous, push type, five zone, slab reheating furnace for minimum fuel usage. Volume I. Text and Appendix A
Temperature control of a continuous, push-type, five-zone, slab-reheating furnace for minimum-fuel usage. Volume I. Text and Appendix A
Method and system for controlling multi-zone reheating furnaces
Technical Report
·
Tue Mar 31 23:00:00 EST 1981
·
OSTI ID:6397505
Temperature control of a continuous, push-type, five-zone, slab-reheating furnace for minimum-fuel usage. Volume I. Text and Appendix A
Technical Report
·
Tue Mar 31 23:00:00 EST 1981
·
OSTI ID:6292877
Method and system for controlling multi-zone reheating furnaces
Patent
·
Mon Nov 01 23:00:00 EST 1982
·
OSTI ID:6536081
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320303* -- Energy Conservation
Consumption
& Utilization-- Industrial & Agricultural Processes-- Equipment & Processes
COMPUTERIZED SIMULATION
CONTROL
CONTROL SYSTEMS
ENERGY CONSUMPTION
FUEL CONSUMPTION
FUEL ECONOMY
FURNACES
ON-LINE CONTROL SYSTEMS
ON-LINE SYSTEMS
SIMULATION
TEMPERATURE CONTROL
TESTING
320303* -- Energy Conservation
Consumption
& Utilization-- Industrial & Agricultural Processes-- Equipment & Processes
COMPUTERIZED SIMULATION
CONTROL
CONTROL SYSTEMS
ENERGY CONSUMPTION
FUEL CONSUMPTION
FUEL ECONOMY
FURNACES
ON-LINE CONTROL SYSTEMS
ON-LINE SYSTEMS
SIMULATION
TEMPERATURE CONTROL
TESTING