Energy analysis of the basic materials utilized in electric power transmission systems
The energy content per mile of installed underground and overhead power transmission systems has been calculated for the following types of systems: self-contained oil-filled cables; HPOF pipe-type cables; extruded dielectric cables; compressed-gas-insulated systems; overhead lines (ac and dc) and two proposed superconducting systems (ac and dc). The system operating voltages analyzed included 138, 230, 345, 500, 765 and 1,200 kV for ac systems, but all systems were not analyzed at the higher voltages. The dc overhead lines operated at +-200, +-400, +-600 and +-800 kV. Total installed energy content for these systems ranged from 4 x 10/sup 9/ to 1.2 x 10/sup 11/ Btu per mile. Installation energy requirements were generally 10% or less of the inherent system energy content based on the materials used in each system. Most of the energy content in each system can be attributed to the metallic components; plastic and insulating oil also contribute significantly. The energy content of 36 materials and basic products, in terms of Btu per ton, was calculated as part of this study. Substitution of conductor materials (e.g., aluminum for copper) in cable systems resulted in changes in the total system energy content on the order of 15%.
- Research Organization:
- Little (Arthur D.), Inc., Cambridge, MA (USA)
- OSTI ID:
- 6270904
- Report Number(s):
- HCP/T5043-01
- Country of Publication:
- United States
- Language:
- English
Similar Records
Evaluation of the economical and technological viability of various underground transmission systems for long feeds to urban load areas. Final report
Development of extruded dielectric underground transmission cables rated 138 kV, 230 kV, and 345 kV. Final report
Development of extruded dielectric underground transmission cables rated 138 kV, 230 kV, and 345 kV. Final report. Volume I
Technical Report
·
Wed Nov 30 23:00:00 EST 1977
·
OSTI ID:5243278
Development of extruded dielectric underground transmission cables rated 138 kV, 230 kV, and 345 kV. Final report
Technical Report
·
Sun Jan 31 23:00:00 EST 1982
·
OSTI ID:5240593
Development of extruded dielectric underground transmission cables rated 138 kV, 230 kV, and 345 kV. Final report. Volume I
Technical Report
·
Sun May 01 00:00:00 EDT 1977
·
OSTI ID:7253642
Related Subjects
200300* -- Electric Power Engineering-- Power Transmission & Distribution-- (-1989)
24 POWER TRANSMISSION AND DISTRIBUTION
AC SYSTEMS
CABLES
CONDUCTOR DEVICES
DATA
DATA FORMS
DC SYSTEMS
ECONOMICS
EHV AC SYSTEMS
EHV DC SYSTEMS
ELECTRIC CABLES
ELECTRICAL EQUIPMENT
ENERGY ANALYSIS
ENERGY CONSERVATION
EQUIPMENT
EXPERIMENTAL DATA
FABRICATION
GAS-INSULATED CABLES
GRAPHS
HVAC SYSTEMS
HVDC SYSTEMS
INFORMATION
INSTALLATION
NUMERICAL DATA
OIL-FILLED CABLES
OPERATION
OVERHEAD POWER TRANSMISSION
POWER SYSTEMS
POWER TRANSMISSION
POWER TRANSMISSION LINES
SUPERCONDUCTING CABLES
TABLES
UHV AC SYSTEMS
UNDERGROUND POWER TRANSMISSION
24 POWER TRANSMISSION AND DISTRIBUTION
AC SYSTEMS
CABLES
CONDUCTOR DEVICES
DATA
DATA FORMS
DC SYSTEMS
ECONOMICS
EHV AC SYSTEMS
EHV DC SYSTEMS
ELECTRIC CABLES
ELECTRICAL EQUIPMENT
ENERGY ANALYSIS
ENERGY CONSERVATION
EQUIPMENT
EXPERIMENTAL DATA
FABRICATION
GAS-INSULATED CABLES
GRAPHS
HVAC SYSTEMS
HVDC SYSTEMS
INFORMATION
INSTALLATION
NUMERICAL DATA
OIL-FILLED CABLES
OPERATION
OVERHEAD POWER TRANSMISSION
POWER SYSTEMS
POWER TRANSMISSION
POWER TRANSMISSION LINES
SUPERCONDUCTING CABLES
TABLES
UHV AC SYSTEMS
UNDERGROUND POWER TRANSMISSION