Generalized fluid meter discharge coefficient based solely on boundary layer parameters
Journal Article
·
· J. Eng. Gas Turbines Power; (United States)
A new fluid-meter discharge coefficient formulation in terms of boundary-layer parameters alone has been developed. Although the coefficient proved to be the most valid for plenum-inlet installations, it also accurately represents pipe installations of fluid meters. The formulation also predicts the characteristics of new fluid-meter designs, such as a cubic nozzle in a pipe installation.
- OSTI ID:
- 6264826
- Journal Information:
- J. Eng. Gas Turbines Power; (United States), Journal Name: J. Eng. Gas Turbines Power; (United States) Vol. 101; ISSN JETPE