Quick-look report on LOFT nonnuclear experiment L3-0

Technical Report ·
OSTI ID:6264708
The preliminary evaluation has been completed of the results from nonnuclear Loss-of-Coolant Experiment (LOCE) L3-0, which was successfully conducted on May 31, 1979, in the Loss-of-Fluid Test (LOFT) facility. LOCE L3-0, the first experiment in the LOFT Small and Intermediate Break Series L3, simulated a small break at the top of the LOFT pressurizer by opening the power operated pressure relief valve. For this experiment, the nuclear core remained installed and in a shutdown condition. The initial conditions and plant configuration were similar to previous nuclear LOCEs performed in experiment Series L2 with the exception of the primary system being isothermal due to the lack of reactor heat input. Selected data, presented in this report, confirm that the objectives of LOCE L3-0 were successfully achieved.
Research Organization:
Idaho National Engineering Lab., Idaho Falls (USA)
DOE Contract Number:
EY-76-C-07-1570
OSTI ID:
6264708
Report Number(s):
QLR-L-3-0
Country of Publication:
United States