The first quarter 1982 report summarizes the operating and test data obtained at the six ton per day Advanced Coal Liquefaction Research and Development Facility in Wilsonville, Alabama. The Wilsonville R and D Facility was in operation 52% of the period with scheduled shutdowns accounting for 33% of the downtime. Illinois 6 coal from the Burning Star No. 2 mine was processed during Run 236. The three process units of the Wilsonville facility were operated in a non-integrated mode to evaluate process parameters and to test equipment and operating modifications. Data were obtained in the following areas: In the SRC Unit: operation at low severity reaction conditions for single stage liquefaction with a high LSRC recycle rate using Illinois 6 coal; process solvent activity control; and preliminary feeding tests with hydrotreated SRC as a replacement for LSRC in the process solvent. In the CSD Unit: operation with T102 Vacuum Column bottoms produced at low severity reaction conditions using Illinois 6 coal; start-up with feed direct from the SRC unit rather than remelted, deashed SRC; modifications to the first stage ash removal system; DAS loss reduction; and alternate DAS utilization. In the HTR Unit: operation on SRC produced at low severity conditions with Illinois 6 coal; product yield and qualities; and catalyst aging.
Research Organization:
Catalytic, Inc., Wilsonville, AL (USA)
DOE Contract Number:
AC22-76ET10154
OSTI ID:
6232002
Report Number(s):
DOE/ET/10154-122; ON: DE83012237
Country of Publication:
United States
Language:
English