Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Discrepancies between film and thermoluminescent dosimetry (TLD) readings at an operating power reactor

Conference · · Am. Soc. Test. Mater., Spec. Tech. Publ.; (United States)
OSTI ID:6231887

The results of exposure measurements using film badges and thermoluminescent dosimetry (TLD) were compared at an operating nuclear power reactor. The film badge overresponded to the high-energy Nitrogen-16 gamma rays produced under power, while the TLD did not. Discussions of charged-particle equilibrium and energy dependence are included. The cause of the overresponse was determined to be the excess pair production electrons created because of the high atomic number in the lead energy-compensating shield surrounding the film and in the film itself.

Research Organization:
Power Authority of the State of New York, Buchanan
OSTI ID:
6231887
Report Number(s):
CONF-780719-
Journal Information:
Am. Soc. Test. Mater., Spec. Tech. Publ.; (United States), Journal Name: Am. Soc. Test. Mater., Spec. Tech. Publ.; (United States) Vol. 698; ISSN ASTTA
Country of Publication:
United States
Language:
English