Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Allowable residual contamination levels for decommissioning, Part 2: a summary of example results

Conference ·
OSTI ID:6231072
This paper contains a description of the results of a study sponsored by UNC Nuclear Industries to determine Allowable Residual Contamination Levels (ARCL) for decommissioning facilities in the 100 Areas of the Hanford Site. ARCL results are presented both for surface contamination remaining in facilities (in dpm/100 cm/sup 2/) and for unconfined surface and confined subsurface soil conditions (in pCi/g). Two confined soil conditions are considered: contamination at depths between 1 and 4 m, and contamination at depths greater than or equal to 5 m. A set of worksheets are discussed for modifying the ARCL values to accommodate changes in the radionuclide mixture or concentrations, to consider the impacts of radioactive decay, and to predict instrument responses. Finally, a comparison is made between the unrestricted release ARCL values for the 100 Area facilities and existing decommissioning and land disposal regulations. For surface contamination, the comparison shows good agreement for a selected annual dose limit. For soil contamination, the comparison shows good agreement if reasonable modification factors are applied to account for the differences in modeling soil contamination and licensed low-level waste.
Research Organization:
Pacific Northwest Lab., Richland, WA (USA)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
6231072
Report Number(s):
PNL-SA-12053; CONF-841187-7-Pt.2; ON: DE85003632
Country of Publication:
United States
Language:
English