The determination of chlorophenoxy acid herbicides by liquid chromatography using carbon-14 tracers
Conference
·
OSTI ID:6228342
The extractive recovery of 2,4-dichlorophenoxyacetic acid (2,4-D) and 2-(2,4,5-trichloro)phenoxypropionic acid (Silvex) from environmental samples was evaluated using carbon-14 tracers of the acid form of both herbicides. Recoveries using methylene chloride or 1:1 methylene chloride:acetone for solids exceeded 75% when the material being extracted was maintained at an acid pH (pH less than or equal to2). Following extraction, the extract is taken to dryness and then dissolved in the solution being used for HPLC elution. Two slightly different isocratic elutions with reversed phase columns were studied. In the first system studied a heavily loaded (18% carbon by weight), completely endcapped C18 reversed phase column was eluted with an aqueous solution of 30% (v/v) acetonitrile that contained 0.001 M concentration of a pH 4.6 acetate buffer. The effluent from this column was monitored at 280 nm. The minimum amount detected, when monitoring at 280 nm, is 100 ng of either Silvex or 2,4-D in the injected sample. A second isocratic elution system avoided the use of a buffered eluent by utilizing a high performance reversed phase column and an aqueous methanol (20% v/v) eluent. This second column has been monitored at multiple wavelengths with a diode array detector. The sensitivity of detection can be greatly increased at wavelengths below 240 nm; however, any real sample must be very ''clean'' in order to avoid interferences when monitoring below 230 nm. Thus monitoring at 280 nm is probably optimal for real environmental samples. At this wavelength the detectable concentration of either herbicide in the solution being injected is 5 ppM for a 20 ..mu..l injection.
- Research Organization:
- Oak Ridge National Lab., TN (USA)
- DOE Contract Number:
- AC05-84OR21400
- OSTI ID:
- 6228342
- Report Number(s):
- CONF-870763-2; ON: DE87011932
- Country of Publication:
- United States
- Language:
- English
Similar Records
Transitory mobile phase environments for rapid selectivity changes in liquid chromatography: application to organic dyestuffs
Improved lipid analysis using a 2D-LC-MS system with a novel injection procedure
Determination of chlorinated phenoxyacid herbicides in water and sediment by solid phase extraction and high-performance liquid chromatography. Final report
Journal Article
·
Wed Dec 31 23:00:00 EST 1986
· Anal. Chem.; (United States)
·
OSTI ID:7007151
Improved lipid analysis using a 2D-LC-MS system with a novel injection procedure
Journal Article
·
Sun Apr 14 20:00:00 EDT 2024
· Journal of Chromatography. B
·
OSTI ID:2345289
Determination of chlorinated phenoxyacid herbicides in water and sediment by solid phase extraction and high-performance liquid chromatography. Final report
Technical Report
·
Sat Oct 31 23:00:00 EST 1992
·
OSTI ID:6615864
Related Subjects
37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CHEMISTRY
400102* -- Chemical & Spectral Procedures
BETA DECAY RADIOISOTOPES
BETA-MINUS DECAY RADIOISOTOPES
CARBON 14
CARBON ISOTOPES
CHROMATOGRAPHY
EVEN-EVEN NUCLEI
HERBICIDES
ISOTOPE APPLICATIONS
ISOTOPES
LIGHT NUCLEI
LIQUID COLUMN CHROMATOGRAPHY
METHYLENE CHLORIDE
NUCLEI
ORGANIC CHLORINE COMPOUNDS
ORGANIC COMPOUNDS
ORGANIC HALOGEN COMPOUNDS
PESTICIDES
RADIOISOTOPES
SEPARATION PROCESSES
TRACER TECHNIQUES
YEARS LIVING RADIOISOTOPES
400102* -- Chemical & Spectral Procedures
BETA DECAY RADIOISOTOPES
BETA-MINUS DECAY RADIOISOTOPES
CARBON 14
CARBON ISOTOPES
CHROMATOGRAPHY
EVEN-EVEN NUCLEI
HERBICIDES
ISOTOPE APPLICATIONS
ISOTOPES
LIGHT NUCLEI
LIQUID COLUMN CHROMATOGRAPHY
METHYLENE CHLORIDE
NUCLEI
ORGANIC CHLORINE COMPOUNDS
ORGANIC COMPOUNDS
ORGANIC HALOGEN COMPOUNDS
PESTICIDES
RADIOISOTOPES
SEPARATION PROCESSES
TRACER TECHNIQUES
YEARS LIVING RADIOISOTOPES