Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Indoor air pollution due to emissions from unvented gas-fired space heaters

Conference ·
OSTI ID:6227529
Operation of an unvented combustion appliance indoors can elevate pollutant concentrations. Under laboratory conditions, we determined the oxygen consumption rates and the pollutant emission rates of CO, CO/sup 2/, NO, NO/sub 2/, HCHO and submicron particles emitted from eight unvented gas-fired space heaters operated with well adjusted air shutters at partial and full input in a 27-m/sup 3/ chamber. Emission rates were also determined for some heaters operating under poorly tuned conditions. Four of the eight heaters were subsequently tested in a 240-m/sup 3/ research house with 0.36 to 1.14 air changes per hour. Based on measurements near steady-state, we projected steady-state pollutant and oxygen levels: 1,930 to 11,100 ppM for CO/sub 2/, 1.0 to 26 ppM for CO (under well-tuned conditions), 0.40 to 1.46 ppM for NO/sub 2/, and 19.1 to 20.7% for O/sub 2/. Concentrations of CO/sub 2/, CO, and NO/sub 2/ were sometimes observed to be above their outdoor or occupational guidelines. Analysis showed that CO, NO, and NO/sub 2/ emission rates can vary with time and that while short-term emission rates derived from laboratory tests were consistent with initial emission rates observed in the field, they did not always correspond to steady-state emission rates.
Research Organization:
Lawrence Berkeley Lab., CA (USA)
DOE Contract Number:
AC03-76SF00098
OSTI ID:
6227529
Report Number(s):
LBL-15878; CONF-830617-6; ON: DE83012875
Country of Publication:
United States
Language:
English