skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Low cycle fatigue behavior of polycrystalline NiAl at 300 and 1000 K

Technical Report ·
OSTI ID:6222775

The low cycle fatigue behavior of polycrystalline NiAl was determined at 300 and 1000 K - temperatures below and above the brittle- to-ductile transition temperature (BDTT). Fully reversed, plastic strain-controlled fatigue tests were conducted on two differently fabricated alloy samples: hot isostatically pressed (HIP'ed) prealloyed powder and hot extruded castings. HIP'ed powder (HP) samples were tested only at 1000 K, whereas the more ductile cast-and-extruded (C+E) NiAl samples were tested at both 1000 and 300 K. Plastic strain ranges of 0.06 to 0.2 percent were used. The C+E NiAl cyclically hardened until fracture, reaching stress levels approximately 60 percent greater than the ultimate tensile strength of the alloy. Compared on a strain basis, NiAl had a much longer fatigue life than other B2 ordered compounds in which fracture initiated at processing-related defects. These defects controlled fatigue life at 300 K, with fracture occurring rapidly once a critical stress level was reached. At 1000 K, above the BDTT, both the C+E and HP samples cyclically softened during most of the fatigue tests in air and were insensitive to processing defects. The processing method did not have a major effect on fatigue life; the lives of the HP samples were about a factor of three shorter than the C+E NiAl, but this was attributed to the lower stress response of the C+E material. The C+E NiAl underwent dynamic grain growth, whereas the HP material maintained a constant grain size during testing. In both materials, fatigue life was controlled by intergranular cavitation and creep processes, which led to fatigue crack growth that was primarily intergranular in nature. Final fracture by overload was transgranular in nature. Also, HP samples tested in vacuum had a life three times longer than their counterparts tested in air and, in contrast to those tested in air, hardened continuously over half of the sample life.

Research Organization:
National Aeronautics and Space Administration, Cleveland, OH (United States). Lewis Research Center
OSTI ID:
6222775
Report Number(s):
N-93-26898; NASA-TM-105987; E-7566; NAS-1.15:105987; CNN: RTOP 510-01-50
Country of Publication:
United States
Language:
English

Similar Records

Low-cycle fatigue behavior of polycrystalline NiAl at 1000 K
Journal Article · Tue Feb 01 00:00:00 EST 1994 · Metallurgical Transactions, A (Physical Metallurgy and Materials Science); (United States) · OSTI ID:6222775

The influence of hydrostatic pressure on fracture of single-crystal and polycrystalline NiAl
Journal Article · Fri Jul 01 00:00:00 EDT 1994 · Metallurgical Transactions, A (Physical Metallurgy and Materials Science); (United States) · OSTI ID:6222775

Manifestations of dynamic strain aging in soft-oriented NiAl single crystals