Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Secondary-water chemistry at Millstone 2

Technical Report ·
OSTI ID:6217563
Secondary system chemistry and steam generator corrosion observations at the Millstone 2 pressurized water reactor are summarized. Condenser retubing and retrofit of full-flow condensate polishers led to significant improvements in steam generator blowdown chemistry following observations of denting after one year of operation at elevated blowdown chloride levels. Notwithstanding the chemistry improvements, denting has continued but at a much reduced rate. In addition, extensive pitting of the Alloy 600 tubing between the tubesheet and first support plate has been reported recently.
Research Organization:
NWT Corp., San Jose, CA (USA)
OSTI ID:
6217563
Report Number(s):
EPRI-NP-2974; ON: DE83902311
Country of Publication:
United States
Language:
English