Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Barrierless ultrasonic air cleaner. Final report

Technical Report ·
OSTI ID:6214016
This report describes an experimental program (SBIR Phase I) to demonstrate the technical feasibility of using an ultrasonic standing-wave field to promote coalescence of airborne dusts in order to improve the separation efficiency of typical inertial separators such as current precleaners. Major project tasks included assembly of an ultrasonic coalescence array; measurement of the dust mass passing through an inertial separator as a function of upstream dust concentration, airflow rate, and ultrasonic power level; and calculation of the improvement in separator efficiency as a function of coalescence. The results clearly demonstrate the technical feasibility of using an ultrasonic standing wave field to alter the particle size distribution of airborne dust in order to improve the performance of existing inertial separators, such as those used for precleaner in state-of-the-art air cleaner systems. Importantly, there is no pressure drop across the standing wave field and hence the problems typically associated with barrier filter loading can be avoided.
Research Organization:
Taylor (S.R.) and Associates, Bartlesville, OK (USA)
OSTI ID:
6214016
Report Number(s):
AD-A-204237/2/XAB
Country of Publication:
United States
Language:
English