Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

An evaluation of the LEC-460 solar collector

Technical Report ·
DOI:https://doi.org/10.2172/6212422· OSTI ID:6212422

The optical performance of the LaJet Energy Corporation's membrane faceted concentrator, Model LEC-460, was evaluated at Sandia National Laboratories, Albuquerque, using a fluxmapper, a device that measures flux intensity in the aperture plane of the collector with a movable Kendall radiometer. Three-dimensional flux intensity plots and flux contour maps were produced from the data, and numerical integration of the data was performed to obtain an estimate of the total integrated power into the aperture plane. The test results, normalized to a reference insolation value of 0.1 W/cm/sup 2/, indicated a peak flux of 172 W/cm/sup 2/ and a total integrated power of 30.2 kW. The net efficiency of the collector in a clean mirror condition was estimated to be 77.4%.

Research Organization:
Sandia National Labs., Albuquerque, NM (USA)
DOE Contract Number:
AC04-76DP00789
OSTI ID:
6212422
Report Number(s):
SAND-87-0852; ON: DE88000052
Country of Publication:
United States
Language:
English

Similar Records

LEC system development
Technical Report · Wed Feb 29 23:00:00 EST 1984 · OSTI ID:6406243

JPL tests of a LaJet concentrator facet
Technical Report · Mon Oct 31 23:00:00 EST 1983 · OSTI ID:6780603

JPL tests of a LaJet concentrator facet
Technical Report · Mon Nov 14 23:00:00 EST 1983 · OSTI ID:6927335