skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Determination of three aldehydes in the air of working environments

Journal Article · · Anal. Lett.; (United States)

The quantitative determination of glutaraldehyde, formaldehyde and acrolein in air samples, taken at hospitals, engine shops and at one garage is described. Known volumes of air were drawn through sampling tubes, containing Amberlite XAD-2, coated with 2.4-dinitrophenylhydrazine as adsorption material. The hydrazones formed were desorbed using acetonitrile as eluent. The separation of these compounds was performed on a RP C-18 column; for detection at lambda = 365 nm an UV spectrophotometer was used. The limits of detection - based on a 3 l air sample and an injection volume of 15 ..mu..l - were estimated to be: for glutaraldehyde 0.02 mg/m/sup 3/ of air; for formaldehyde 0.04 mg/m/sup 3/ of air; for acrolein 0.015 mg/m/sup 3/ of air (at 95% conf. level). 11 references, 2 figures, 2 tables.

Research Organization:
Danish Engineering Academy, Lyngby
OSTI ID:
6207441
Journal Information:
Anal. Lett.; (United States), Vol. 18:A19
Country of Publication:
United States
Language:
English