Fuzzy logic controllers for electric motors and wind turbines. Report for October 1996-April 1997
Technical Report
·
OSTI ID:620590
The paper discusses a precision laboratory test facility that has been assempbled to test the performance of two fuzzy-logic based controllers for electric motors and wind turbines. Commercial induction motors up to 10 hp (7.46 kWe) in motors and equipped with adjustable-speed drives (ASDs) were used to test the motor optimizers.
- Research Organization:
- Environmental Protection Agency, Research Triangle Park, NC (United States)
- OSTI ID:
- 620590
- Report Number(s):
- PB--98-140338/XAB; EPA--600/A-98/013
- Country of Publication:
- United States
- Language:
- English