Reference dosimetry for various Health Physics Research Reactor spectra

Technical Report ·
DOI:https://doi.org/10.2172/6188916· OSTI ID:6188916
Reference neutron dosimetry is developed in a consistent and reproducible manner for five different Health Physics Research Reactor (HPRR) spectra: the unshielded HPRR, the HPRR shielded by 20-cm concrete, by 12-cm Lucite, by 13-m steel, and by a 5-cm steel/15-cm concrete shield. The reference dosimetry is presented in two forms so as to be of maximum usefulness both to dosimetrists and to reactor operations personnel. The forms are: (1) dosimetric data (i.e., wet tissue kerma, element 57 dose, and element 57 dose equivalent) per unit fluence at 3 m from the centerline of the HPRR, and (2) dosimetric data at 3 m from the centerline of the HPRR per fission in the reactor. A large amount of HPRR dosimetry-related information are included and form a comprehensive compilation of available data. These data include calculated HPRR neutron energy spectra for each of the five above mentioned shielding situations, dosimetric data per unit fluence as a function of neutron energy, dosimetric contributions to the total reference values by neutron energy group, quality factors, shield attenuation factors and a summary of nuclear engineering data for each shield, kerma variation with distance from the HPRR, and a summary of previously published reference dosimetry-related HPRR data.
Research Organization:
Oak Ridge National Lab., TN (USA)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA), Nuclear Criticality Safety Program (NCSP)
DOE Contract Number:
W-7405-ENG-26
OSTI ID:
6188916
Report Number(s):
ORNL/TM-7748; ON: DE81025851
Country of Publication:
United States
Language:
English