Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

A Schottky receiver for non-perturbative tune monitoring in the Tevatron

Conference ·
OSTI ID:6178309
Transverse Schottky noise and coherent betatron modulation of the bunched beam revolution harmonics are continuously monitored by a sensitive receiver. The electronics relies upon low noise amplifiers, narrow-band filters, and spectrally pure oscillators to obtain a minimum detectable signal of -160 dBm. Dynamic range is 80 dB. Separate baseband proton and antiproton signals are continuously analyzed in the Main Control Room.
Research Organization:
Fermi National Accelerator Lab., Batavia, IL (USA)
DOE Contract Number:
AC02-76CH03000
OSTI ID:
6178309
Report Number(s):
FNAL/C-89/73; CONF-890335-94; ON: DE89011453
Country of Publication:
United States
Language:
English