Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Test of a cryogenic helium pump

Conference · · Adv. Cryog. Eng.; (United States)
OSTI ID:6177610

A cryogenic helium pump is described with detailed schematic drawings. The test setup and results are given and the pump characteristics charted. The calculations for the thermal efficiency are presented with mass flow rate as a function of pump speed shown on a chart. Conclusions include the fact that a helium pump of this type would be suitable for the use of flowing supercritical helium through ICS magnets. It has pumped supercritical helium up to 7.5 atm with a pump head up to 2.8 atm.

Research Organization:
Oak Ridge National Lab., Oak Ridge, TN
OSTI ID:
6177610
Report Number(s):
CONF-810835-
Journal Information:
Adv. Cryog. Eng.; (United States), Journal Name: Adv. Cryog. Eng.; (United States) Vol. 27; ISSN ACYEA
Country of Publication:
United States
Language:
English