A cryopump-operated rotating nuclear demagnetization cryostat for research on superfluid sup 3 He

Journal Article · · Journal of Low Temperature Physics; (USA)
DOI:https://doi.org/10.1007/BF00682269· OSTI ID:6169902
The authors have constructed a rotating submillikelvin cryostat in which the dilution refrigerator can be operated in a continuous mode using two cryopumps. The {sup 4}He pot is also equipped with similar pumps. The dilution unit is employed to precool a nuclear stage with 32 mol of copper in an 8-T field. In the design, special care was taken to make fast rotations possible. The apparatus is currently used to measure collective mode phenomena in superfluid {sup 3}He-B.
OSTI ID:
6169902
Journal Information:
Journal of Low Temperature Physics; (USA), Journal Name: Journal of Low Temperature Physics; (USA) Vol. 76:1-2; ISSN 0022-2291; ISSN JLTPA
Country of Publication:
United States
Language:
English

Similar Records

Nuclear-demagnetization cryostat and cryostat for dissolving 3 He in 4 He with high cooling performance
Journal Article · Sat Nov 30 23:00:00 EST 1985 · Instrum. Exp. Tech. (Engl. Transl.); (United States) · OSTI ID:5496229

Nuclear demagnetization cryostat at University of Florida Microkelvin Laboratory
Journal Article · Sat Oct 31 23:00:00 EST 1992 · Journal of Low Temperature Physics · OSTI ID:138626

Dry demagnetization cryostat for sub-millikelvin helium experiments: Refrigeration and thermometry
Journal Article · Fri Aug 01 00:00:00 EDT 2014 · Review of Scientific Instruments · OSTI ID:22327830