Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Comparison of thallium-201 and technetium-99m hexakis 2-methoxyisobutyl isonitrile single-photon emission computed tomography for estimating the extent of myocardial ischemia and infarction in coronary artery disease

Journal Article · · American Journal of Cardiology; (USA)

Single-photon emission computed tomography (SPECT) using thallium-201 (Tl-201) was compared with technetium-99m hexakis 2-methoxyisobutyl isonitrile (Tc-99m MIBI) in 24 patients with coronary artery diseaes. Patients exercised to the same work load as each isotope was studied. Normal and hypoperfused left ventricular mass was determined with an automated method. Estimated total left ventricular mass was similar for both stress/redistribution Tl-201 and stress/rest Tc-99m MIBI images. The mean estimated defect size in the redistribution Tl-201 images was 32 +/- 34.7 vs 33 +/- 38.4 g in the resting Tc-99m MIBI studies (difference not significant). The individual determinations of defect mass were highly correlated (r = 0.93; p less than 0.0001). Estimated defect size in the stress Tl-201 images (52 +/- 46.2 g) was significantly larger than the exercise Tc-99m MIBI estimates of defect mass (42 +/- 39.9 g; p less than 0.05). A linear correlation existed between stress thallium and technetium estimates of defect size (r = 0.85) but 15 of 24 Tc-99m MIBI defects were smaller than the Tl-201 defects. Partial redistribution of Tc-99m MIBI could explain the discordance. Stress Tc-99m MIBI SPECT defect size determined by visual interpretation or by the use of isocount analysis may be smaller than what is seen with stress Tl-201 SPECT.

OSTI ID:
6169732
Journal Information:
American Journal of Cardiology; (USA), Journal Name: American Journal of Cardiology; (USA) Vol. 66:20; ISSN 0002-9149; ISSN AJCDA
Country of Publication:
United States
Language:
English

Similar Records

Simultaneous assessment of left ventricular wall motion and myocardial perfusion with technetium-99m-methoxy isobutyl isonitrile at stress and rest in patients with angina: Comparison with thallium-201 SPECT
Journal Article · Sat Mar 31 23:00:00 EST 1990 · Journal of Nuclear Medicine; (USA) · OSTI ID:7192865

Myocardial redistribution of technetium-99m-methoxyisobutyl isonitrile (SESTAMIBI)
Journal Article · Fri Jun 01 00:00:00 EDT 1990 · Journal of Nuclear Medicine; (USA) · OSTI ID:6697664

Comparison of technetium 99m methoxy isobutyl isonitrile and thallium 201 for evaluation of coronary artery disease by planar and tomographic methods
Journal Article · Sat Dec 31 23:00:00 EST 1988 · Am. Heart J.; (United States) · OSTI ID:6499510