The custom weighting-factor loads calculative method that was implemented in the DOE-2.1 program was refined and fully documented. This method allows direct-gain and night-ventilative-cooling passive systems to be analyzed using DOE-2. A thermal storage wall model for DOE-2 was developed and tested.This model treats vented and unvented storage walls using either masonry or water as the storage medium. It includes the effect of night insulation and selective surfaces. A model for attached sunspaces, atriums, and buffer spaces has also been developed for DOE-2. This model simulates interzone convection (forced or natural), and interzone conduction through massive walls. A case study of Warner Hall at Carnegie-Mellon University in Pittsburgh, Pennsylvania was completed, as part of the DOE Passive Solar Commercial Buildings Program. DOE-2 was used in an analysis of several passive solar and energy conservation retrofit options. The Los Alamos analysis served as a basis for comparison to a more limited (in time and budget) analysis done by the energy consultant for the retrofit project.

Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
6168392
Report Number(s):
LA-UR-81-2209; CONF-810832-4; ON: DE81028737
Resource Relation:
Conference: DOE passive and hybrid solar energy program update, Washington, DC, USA, 9 Aug 1981