Tube vibration in industrial-size test heat exchanger (90/sup 0/ square layout)

Technical Report ·
DOI:https://doi.org/10.2172/6165810· OSTI ID:6165810
Tube vibrations in heat exchangers are being systematically investigated in a series of tests performed with an industrial-size test exchanger. Results from waterflow tests of eleven different tube bundles, in six- and eight-crosspass configurations on a 90/sup 0/ square layout with a pitch-to-diameter ratio of 1.25 are reported. The test cases include full tube bundles, no-tubes-in-window bundles, finned tube bundles, and proposed field and design fixes. The testing focused on identification of the lowest critical flowrate to initiate fluidelastic instability (large amplitude tube motion) and the location within the bundle of the tubes which first experience instability. The test results are tabulated to permit comparison with results obtained from previous tests with a 30/sup 0/ triangular layout tube bundle. Instability criteria are evaluated preliminarily. Pressure drop data are also generated and reported.