Decontamination and decommissioning of the MTR-603 HB-2 cubicle. Final report

Technical Report ·
OSTI ID:6164941

This report describes the decontamination and decommissioning (D and D) of the MTR-603 HB-2 cubicle located at the Idaho National Engineering Laboratory (INEL). The HB-2 cubicle became radioactively contaminated during out-of-pile circulating water loop experiments conducted in the Materials Testing Reactor in the 1950s and 1960s. This report describes work performed to accomplish the D and D objectives of reducing the high radiation fields caused by contamination inside the cubicle, preventing future contamination spread, and making about 1400 ftS of floor space available for reuse. D and D of the HB-2 cubicle consisted of total dismantlement of the cubicle and its contents.

Research Organization:
EG and G Idaho, Inc., Idaho Falls (USA)
DOE Contract Number:
AC07-76ID01570
OSTI ID:
6164941
Report Number(s):
EGG-2431; ON: DE86005758
Country of Publication:
United States
Language:
English