Switch to MDEA raises capacity
Journal Article
·
· Hydrocarbon Process.; (United States)
OSTI ID:6160697
Canada's first plant conversion from DEA to MDEA is a success. Dome's North Caroline amine plant performs very smoothly after being debottlenecked to, at least, original design capacity. Performance data taken for the absorber at several amine flow rates compare with safe accuracy to values calculated by the TSWEET program that was used as the basis for conversion.
- Research Organization:
- Dome Petroleum Ltd., Calgary, Alberta
- OSTI ID:
- 6160697
- Journal Information:
- Hydrocarbon Process.; (United States), Journal Name: Hydrocarbon Process.; (United States) Vol. 63:5; ISSN HYPRA
- Country of Publication:
- United States
- Language:
- English
Similar Records
Simulation values prove out in DEA to MDEA switch
Converting to DEA/MDEA mix ups sweetening capacity
Amine plant troubleshooting and optimization
Journal Article
·
Mon Aug 06 00:00:00 EDT 1984
· Oil Gas J.; (United States)
·
OSTI ID:6410754
Converting to DEA/MDEA mix ups sweetening capacity
Journal Article
·
Mon Aug 12 00:00:00 EDT 1996
· Oil and Gas Journal
·
OSTI ID:276601
Amine plant troubleshooting and optimization
Journal Article
·
Fri Mar 31 23:00:00 EST 1995
· Hydrocarbon Processing
·
OSTI ID:40342