skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Collection efficiency of an ionization chamber in a pulsed and magnetically swept electron beam: limits of validity of the two-voltage technique

Journal Article · · Med. Phys.; (United States)
DOI:https://doi.org/10.1118/1.595538· OSTI ID:6140299

The two-voltage method of determining the collection efficiency of an ionization chamber exposed to a pulsed and magnetically swept electron beam depends upon the form of the saturation curve agreeing closely with the formula based on ionic conduction and negligible space charge. The possible disturbing effects of charge transport by free electrons and of overlapping pulses are discussed and the conditions to be satisfied for the reliable use of the method are defined and demonstrated experimentally.

Research Organization:
Riyadh Armed Forces Hospital, Kingdom of Saudi Arabia
OSTI ID:
6140299
Journal Information:
Med. Phys.; (United States), Vol. 11:4
Country of Publication:
United States
Language:
English